Anti-Proximal Nephrogenic Antigen Antibody Clone PN-15

$ 429.00

SKU: 768-MSM3
Species: Human and Horse
Tested Applications: Flow Cytometry, Immunofluorescence, Western Blot, Immunohistochemistry (IHC)
Available Conjugates: Unconjugated
Isotype: Mouse IgG2b kappa
Mass Spec Validated?: Not MS Validated

 PDF Datasheet

Human and Horse Anti-Proximal Nephrogenic Antigen Antibody Product Attributes

Species: Human and Horse
Tested Applications: Flow Cytometry, Immunofluorescence, Western Blot, Immunohistochemistry (IHC).
Application Notes: Flow Cytometry (0.5-1ug of antibody/million cells in 0.1ml), Immunofluorescence (1-2ug of antibody/ml), Western Blot (0.5-1ug of antibody/ml), Immunohistochemistry (IHC) (Formalin-fixed) (0.5-1ug of antibody/ml for 30 minutes at RT)
Clonality: Monoclonal
Anti-Proximal Nephrogenic Antigen Antibody Clone: PN-15
Clone PN-15 Host and Isotype: Mouse IgG2b kappa
Anti-Human and Horse Proximal Nephrogenic Antigen Positive Control Sample: Normal kidney or renal cell carcinoma
Cellular Localization of Antibody Cell surface, cytoplasmic
Buffer and Stabilizer: 10mM PBS with 0.05% BSA & 0.05% azide.
Antibody Concentration: 200ug/ml
Antibody Purification Method:Protein A/G Purified
Immunogen: Microsomal fraction of human renal cortical tissue homogenate
Storage Conditions: Store at 2 to 8° C (refrigerate). Stable for 24 months when properly stored.

Proximal Nephrogenic Antigen Previously Observed Antibody Staining Patterns

Observed Subcellular, Organelle Specific Staining Data:

Anti-CA9 antibody staining is expected to be primarily localized to the plasma membrane and cytosol.

Observed Antibody Staining Data By Tissue Type:

Variations in Proximal Nephrogenic Antigen antibody staining intensity in immunohistochemistry on tissue sections are present across different anatomical locations. An intense signal was observed in glandular cells in the gallbladder, stomach. More moderate antibody staining intensity was present in glandular cells in the gallbladder, stomach. Low, but measureable presence of Proximal Nephrogenic Antigen could be seen in. We were unable to detect Proximal Nephrogenic Antigen in other tissues. Disease states, inflammation, and other physiological changes can have a substantial impact on antibody staining patterns. These measurements were all taken in tissues deemed normal or from patients without known disease.

Observed Antibody Staining Data By Tissue Disease Status:

Tissues from cancer patients, for instance, have their own distinct pattern of Proximal Nephrogenic Antigen expression as measured by anti-Proximal Nephrogenic Antigen antibody immunohistochemical staining. The average level of expression by tumor is summarized in the table below. The variability row represents patient to patient variability in IHC staining.

Sample Type breast cancer carcinoid cervical cancer colorectal cancer endometrial cancer glioma head and neck cancer liver cancer lung cancer lymphoma melanoma ovarian cancer pancreatic cancer prostate cancer renal cancer skin cancer stomach cancer testicular cancer thyroid cancer urothelial cancer
Signal Intensity
CA9 Variability + + + + + + + + + + + + + + ++ + ++ + + ++

Limitations and Warranty

enQuire Bio’s Proximal Nephrogenic Antigen Anti-Human, Horse Monoclonal is available for Research Use Only. This antibody is guaranteed to work for a period of two years when properly stored.
Size

Tag

Buffer and Stabilizer

,

Product Type

Host

Isotype

Applications

,

Species

Mass Spec Validated?

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Anti-Proximal Nephrogenic Antigen Antibody Clone PN-15

https://enquirebio.com/wp-content/uploads/2017/10/enQuire-Bio-768-MSM3-P1-anti-Proximal-Nephrogenic-Antigen-antibody-300x225.jpeg